Using Technician Interface Scripts
2-450
line {configuration | parameters}
The display includes the following information:
configuration Displays the configuration of the PPP line and the state of the Line
Control Protocol (LCP).
Circuit Name of the circuit the protocol runs on.
Line.LLIndex Line number associated with the circuit; always 0 for now.
LCP State State of the Line Control Protocol — either Disabled, or if Enabled,
any of the states listed under the
alerts command.
Restart Time Number of seconds the Restart Timer waits before retransmitting
data. The maximum value is 1000.
Echo Request Frequency Number of seconds between transmissions of Echo Request
Packets.
Echo Reply Loss Number of unacknowledged Echo-Reply packets counted before
declaring the point-to-point link down.
Maximum Conf-Req Maximum number of unacknowledged configuration requests to
send without receiving a valid response from the peer router on the
other end of the link.
Maximum Term-Req Maximum number of terminate requests to send without receiving a
valid response and before assuming the peer router on the other end
of the link is unavailable.
Max Conf Fail Maximum number of Configure Nak packets to send before
sending a Configure Ack and before assuming that the
configuration does not converge.