Using Technician Interface Scripts
2-126
sample
[
<
period in seconds
>
] [circuit
<circuit name>
]
Displays data sampled from BISYNC over a period of 10 seconds. You can change the
number of seconds over which you want to sample the data, and you can display sampled
data for a specific circuit only.
The table includes the following information:
Sample Display – show bisync sample
BISYNC Sampled Data over 10 seconds
----------------------------------
Rx Tx Rx Lack of Tx Lack of
Slot Conn Circuit Frames Frames RescsChar RescsFrms
---- ---- -------- ---------- ---------- ---------- ----------
1 1 S11 16 4 0 0
1 entry in table.
Slot Slot identifier
Conn Connector identifier
Circuit Name of the circuit associated with this line.
Rx Frames Number of frames received on this line.
Tx Frames Number of frames sent on this line.
Rx Lack of Resources Number of packets received and discarded because of lack of
resources; for example, buffers.
Tx Lack of Resources Number of transmit packets discarded because of lack of resources;
for example, buffers.