interfaces
Displays information about each interface:
Sample Display – show nbip interfaces
NBIP Interfaces
---------------
Input Output Name Input Input Output
IP Address State Bcasts Bcasts Caching Packets Errors Packets
--------------- -------- ------ ------ ------- ---------- ---------- ----------
130.1.1.1 Up Yes Yes Yes 10 0 65
131.1.1.1 Up Yes Yes Yes 68 0 7
192.32.14.92 Down Yes No No 0 0 0
3 Entries.
IP Address IP address of this interface.
State State of the protocol on the interface: Up, Down, Init, or Not
Present.
Input Bcasts Indicates whether the input of NetBIOS broadcasts is enabled.
Output Bcasts Indicates whether the output of NetBIOS broadcasts is enabled.
Name Caching Indicates whether NetBIOS name caching is enabled.
Input Packets Number of frames that have been received by this interface.
Input Errors Number of invalid frames that have been received by this interface.
Output Packets Number of frames that have been transmitted by this interface.