Reading the Event Log
308656-14.00 Rev 00
A-19
The following messages indicate that you configured the port for Raise DTR,
rather than V.25bis, and remind you to check the modem connection:
# 38: mm/dd/yy 14:14:04.100 INFO SLOT 2 MODEMIF Code: 22
Connector COM2: enable requested on cct 65535
Connector COM2: Starting, raise dtr mode, is modem connected and
turned on?
The following messages appear even if you did not connect a modem to the router.
Unlike V.25bis, Raise DTR does not look for a pin signal to detect whether the
port is attached to a modem.
# 39: mm/dd/yy 14:14:04.104 INFO SLOT 2 MODEMIF Code: 52
Connector COM2: Circuit has been brought up.
# 40: mm/dd/yy 14:14:04.104 DEBUG SLOT 2 SWSERV Code: 46
Line Mgr received line ready for line 2
# 41: mm/dd/yy 14:14:04.104 INFO SLOT 2 SWSERV Code: 10
Sync Line 2 available for dial on demand pool 2.
# 42: mm/dd/yy 14:14:04.108 INFO SLOT 2 SYNC Code: 11
Connector COM2 providing LLC1 service.
# 43: mm/dd/yy 14:14:04.636 DEBUG SLOT 2 SWSERV Code: 46
Connector COM2: FSM State: RDTR_WAIT_DATA_OR_IND(1)
Connector COM2: FSM Event: RDTR_EVENT_CD_UP(6); isdn flags: 0x24
# 44: mm/dd/yy 14:15:07.770 INFO SLOT 2 SWSERV Code: 23
Data received for dial on demand circuit 3.
The log messages stop here until you connect and turn on a modem. After you do
this, the router raises DTR to signal the local modem to dial the phone number of
the remote modem. The router then pings the remote side of the dial-on-demand
link, and displays a
DATA Available
message when it receives a response.
# 45: mm/dd/yy 14:15:07.774 DEBUG SLOT 2 SWSERV Code: 46
Connector COM2: FSM State: RDTR_WAIT_DATA_OR_IND(1)
Connector COM2: FSM Event: RDTR_EVENT_DATA_AVAIL(5); isdn flags:
0x2c
# 46: mm/dd/yy 14:15:07.774 TRACE SLOT 2 MODEMIF Code: 34
Connector COM2: DATA Available.
The software assigns a valid circuit number to the line.
# 47: mm/dd/yy 14:15:07.774 DEBUG SLOT 2 SWSERV Code: 44
SW Sent you are cc 3 message to line 2
# 48: mm/dd/yy 14:15:07.782 INFO SLOT 2 SWSERV Code: 7
Dial on demand circuit being established on line 2.
Komentáře k této Příručce