Troubleshooting an Operational Problem
308656-14.00 Rev 00
3-5
Troubleshoot an ASN as follows:
a.
If the ASN is in a stack, make sure that the SPEX slot dial on the rear
panel of each ASN points to a different slot ID. Turn the selector in
either direction so that the arrow on the selector points to the ID you
want to use (Figure 3-1
).
Figure 3-1. Verifying the Slot ID on an ASN
Make sure that the configuration matches the slot dial setting.
b.
If the SPEX net module does not support hot-swap, make sure that a
terminator plug connects to any unused ports labeled SPEX IN and
SPEX OUT.
Make sure that the thumbscrews on the terminator plug are tight.
If the ASNs are in a stack and do not support hot-swap, you must
terminate the SPEX IN port of the first ASN and the SPEX OUT port of
the last ASN. Make sure that, for the remaining ASNs in the stack, the
SPEX OUT port of one ASN connects to the SPEX IN of the next ASN.
Note:
For troubleshooting purposes, the ASN cables are long enough to skip
one ASN in the stack.