Avaya Troubleshooting Routers Průvodce řešením problémů Strana 90

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 268
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 89
Troubleshooting Routers
5-12
308656-14.00 Rev 00
Check the wfKernelEntry for the slot where the problem is occurring to
determine whether buffers are available or whether something on the
network is preventing the router from updating its buffer lists. To do this,
use the command
get wfKernelEntry.*.
<slot>
. For example, enter the
command
get wfKernelEntry.*.2. The router reports the number of
available buffers in slot 2.
Check for protocol storms (for example, from IP RIP, IPX RIP, and SAP,
and learning bridge reconverging). If no buffers are available, check the
configuration of the line and the line utilization.
Increase the wfCSMACDCfgRxQueueLength to 64 and see if that helps
alleviate the problem.
wfCSMACDTooLongErrorTx
This shows the number of frames received that exceed 1518 octets. The
router drops the frames because of a lack of space on the transmission
queue (Tx). Some lack-of-resource errors are likely, especially when the
router boots. If this number increases to a high rate (such as 15/minute)
for an extended period, it may indicate a problem.
Check the wfKernelEntry for the slot where the problem is occurring to
determine whether buffers are available or whether something on the
network is preventing the router from updating its buffer lists. To do this,
enter the command
get wfKernelEntry.*.
<slot>
. For example, enter the
command
get wfKernelEntry.*.2. The router reports the number of
available buffers in slot 2.
Check for protocol storms (for example, from IP RIP, IPX RIP, and SAP,
and learning bridge reconverging). If no buffers are available, check the
configuration of the line and the line utilization.
Increase the wfCSMACDCfgRxQueueLength to 64 and see if that helps
alleviate the problem.
wfCSMACDMerr
This shows the number of Ethernet controller chip memory errors. The
controller chip declares an error when it fails to access memory within
1512 clock ticks of asserting its data strobe signal. After declaring a
memory error, the controller chip reinitializes. Go to “Memory or Buffer
Problem” in Chapter 3.