Customizing Signaling
117374-C Rev 00
5-5
Assigning the UNI Signaling Protocol Standard
The UNI signaling protocol standard specifies how the interface defines Service
Specific Connection Oriented Protocol (SSCOP) frames. The ATM Forum
Versions 3.0 and 3.1 methods of defining SSCOP frames are incompatible.
You must assign the same protocol standard for both the router interface and the
switch interface to which this interface connects. Accept the default, ATM Forum
UNI Version 3.0, if the switch interface uses ATM Forum UNI Version 3.0 to
define SSCOP frames. Change the UNI signaling standard to UNI Version 3.1 if
the switch interface uses ATM Forum UNI Version 3.1 to define SSCOP frames.
Using the BCC
To change the UNI version, navigate to the signaling prompt (for example,
box; atm/11/1; signaling/11/1
) and enter:
uni-version
<version>
version
is the UNI signaling version, either v30 (default) or v31.
For example, the following command changes the UNI signaling protocol
standard to Version 3.1.
signaling/11/1# uni-version v31