Monitoring ATM Using the BCC show Command
117374-C Rev 00
B-11
show dsx3 circuits
The
show dsx3 circuits
command displays information about the DSX3 circuits in the
configuration.
The output includes the following information:
Slot/<Module>/Conn The slot, module, and connector number of the DSX3 circuit.
Circuit The name of the circuit associated with this line.
Sec into Interval The number of seconds into the current 15-minute interval.
# of Intervals The number of complete 15-minute intervals. The value is 96 unless
the interface was brought online within the last 24 hours. In that
case, the value is the number of complete 15-minute intervals since
the interface has been online.
Line Coding The line coding on this circuit. The line coding options are:
•B3ZS
• HDB3
The line coding specifies patterns of normal bits and bipolar
violations used to replace sequences of zero bits of a certain length.
Line Type Status The line status of the interface. The possible status values are:
•
NoAlarm
- no alarm present
•
RRAI
- receiving yellow remote alarm indication
•
TRAI -
transmitting yellow remote alarm indication
•
RAIS
- receiving Alarm Indications Signal (AIS) failure state
•
TA I S
- transmitting AIS failure state
•
LOF
- receiving Loss of Frame (LOF) failure state
•
LOS
- receiving Loss of Signal (LOS) failure state
•
Loopback
- looping the received signal
•
TestCode
- receiving a test pattern
•
LowSignal
- low signal