Configuring ATM and MPLS Services
5-18
117374-C Rev 00
restart-request-tx-
channel-timer
T316c 120 1 to 720 Specifies the Restart Request Sent on Channel
timer value (in seconds). This timer begins when
the circuit sends a RESTART message to the
network. The circuit uses the RESTART message to
return this individual VC on the interface to the idle
condition.
The Restart Request Sent on Channel timer stops
when the circuit receives a RESTART
ACKNOWLEDGE message from the network.
If the timer expires before the circuit receives a
RESTART ACKNOWLEDGE message, the circuit
can retransmit the RESTART message (see
“Setting the Number of Allowable Restart
Messages” on page 5-22). If the circuit still does not
receive a response, the circuit enters the null state
until the appropriate maintenance action is taken.
status-enquiry-tx-
timer
T322 4 1 to 24 Specifies the Status Enquiry Sent timer value (in
seconds). This timer begins when the circuit sends
a STATUS ENQUIRY message to the network. This
message checks the validity of a call by requesting
the call state (that is, active, in progress, or null).
The Status Enquiry Sent timer stops when the
circuit receives a STATUS message from the
network.
If the timer expires before the circuit receives a
STATUS message, the circuit can retransmit the
STATUS ENQUIRY message (see “Setting the
Number of Allowable Status Enquiries” on
page 5-23
). If the circuit still does not receive a
response, the circuit clears the call.
(continued)
Table 5-1. Signaling Timer Descriptions
(continued)
BCC
Name
Site
Manager
Name
Default
Value Range Description