Customizing Signaling
117374-C Rev 00
5-63
Using Site Manager
To change an SSCOP/SAAL timer value, complete the following tasks:
Defining PDU Values
SSCOP/SAAL allows you to customize several values that control PDUs.
Setting the SSCOP Maximum Connection Control Value
The SSCOP maximum connection control value sets the maximum number of
times the sender can transmit a BGN, END, RS, or ER PDU.
By default, the sender can transmit up to four of these messages. However, you
can set this parameter to any value from 1 to 20 messages.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
Signaling AAL (SAAL)
. The ATM Signaling AAL Records List
window opens.
4. Set one or more of the following
parameters:
Poll Timer
Keep Alive Timer
No Response Timer
Connection Control Timer
Click on
Help
or see the parameter
descriptions beginning on page A-64.
5. Click on
Done
. You return to the Edit ATM Connector
window.
6. Click on
Done
. You return to the Select Connection Type
window.
7. Click on
Done
. You return to the Configuration Manager
window.