Configuring ATM and MPLS Services
5-60
117374-C Rev 00
To change link connection arbitration to active, navigate to the SSCOP prompt
and enter:
link-connect-arbitration active
For example, the following command specifies that SSCOP initiates connections:
sscop/11/1# link-connect-arbitration active
sscop/11/1#
Using Site Manager
To set the SSCOP link arbitration state, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
Signaling AAL (SAAL)
. The ATM Signaling AAL Records List
window opens.
4. Set the
Link Connection Arbitration
parameter. Click on
Help
or see the
parameter description on page A-63.
5. Click on
Done
. You return to the Edit ATM Connector
window.
6. Click on
Done
. You return to the Select Connection Type
window.
7. Click on
Done
. You return to the Configuration Manager
window.