Site Manager Parameters
117374-C Rev 00
A-67
MPOA Parameters
This section describes the MPOA parameters for configuring an ATM MPOA
server (MPS).
Parameter: Max STAT PDU Elements
Path: Configuration Manager > Circuits > Edit Circuits >
Edit
>
ATM
>
Signaling
AAL (SAAL)
Default: 67
Options: Odd integer from 3 to 119
Function: Specifies the SSCOP maximum STAT PDU value. This value sets the maximum
number of list elements allowed in a STAT PDU.
The sending device uses the value of this parameter for segmentation purposes.
When the number of list elements exceeds this value, the STAT message
segments. As a general rule, the default value, 67, causes the STAT PDU to fill
six ATM cells using AAL 5.
Instructions: Accept the default, 67, or enter an odd integer from 3 to 119.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.15
Parameter: Enable/Disable
Path: Configuration Manager > Circuits > Edit Circuits >
Edit
>
ATM
>
MPOA
Server Attributes
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables the MPOA service record on this interface.
Instructions: Accept the default, Enable, if you want the MPOA service record to remain
enabled on this interface. Select Disable if you do not want the MPOA service
record enabled on this interface.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.10.1.1.2