Site Manager Parameters
117374-C Rev 00
A-45
Parameter: T303
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 4
Options: 1 to 24
Function: Specifies the Setup Sent timer value (in seconds). This timer begins when the
circuit initiates a call/connection request by sending a SETUP message over the
signaling VC.
The Setup Sent timer stops when the circuit receives a CONNECT message
(indicating connection), a CALL PROCEEDING message (indicating that the
network received the SETUP message), or a RELEASE COMPLETE message
(indicating the rejection of the SETUP message) from the network.
If the circuit does not receive one of these messages within the allotted time, it
transmits the SETUP message again. If the circuit still does not receive a
response, it clears the connection.
Instructions: Accept the default, 4, or enter a value from 1 to 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.25