Configuring ATM and MPLS Services
10-2
117374-C Rev 00
Setting the ATM Router Redundancy Monitoring Timer
Bay Networks ATM router redundancy uses only one ATM-specific Site Manager
parameter: ATM Monitoring Timer.
The ATM monitoring timer specifies the amount of time in milliseconds (ms) that
the secondary router waits before beginning the process of becoming the primary
router. By default, if the primary router experiences a loss of signal, it waits
3000 ms for the signal to return. If the signal does not return within that time, the
secondary router begins the process of becoming the primary router.
You can set the ATM monitoring timer to any value from 1 to 65,535 ms.
To set the ATM monitoring timer, complete the following tasks:
Note:
For instructions on how to start ATM router redundancy, see “Starting
ATM Router Redundancy” on page 3-23. For instructions on how to customize
all other router redundancy parameters, see Configuring Interface and Router
Redundancy.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
Configure ATM Router
Redundancy
.
The Router Redundancy Circuit window
opens.
4. Set the
ATM Monitoring Timer
parameter. Click on
Help
or see the
parameter description on page A-75.
5. Click on
OK
. You return to the Edit ATM Connector
window.
6. Click on
Done
. You return to the Select Connection Type
window.
7. Click on
Done
. You return to the Configuration Manager
window.