Configuring ATM and MPLS Services
5-38
117374-C Rev 00
To change the ILMI VPI number, complete the following tasks:
Changing VCI Numbers
By default, the VCI for the signaling control VC is 5 and the VCI for the ILMI
control VC is 16. However, you can change the VCI number to any value from 1
to 65535.
Using the BCC
To change the signaling VCI number, navigate to the signaling prompt (for
example,
box; atm/11/1; signaling/11/1
) and enter:
vci
<integer>
integer
is the VCI number that you want the signaling VC to use.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
Interim Local Management
Interface (ILMI)
.
The ATM ILMI Signaling Parameters
window opens.
4. Click on
ILMI VC
. The ATM Control VC for ILMI window
opens.
5. Set the
ILMI VPI
parameter. Click on
Help
or see the parameter description on
page A-55.
6. Click on
Done
. You return to the ATM ILMI Signaling
Parameters window.
7. Click on
Done
. You return to the Edit ATM Connector
window.
8. Click on
Done
. You return to the Select Connection Type
window.
9. Click on
Done
. You return to the Configuration Manager
window.
Komentáře k této Příručce