Avaya Configuring ATM and MPLS Services Uživatelský manuál Strana 214

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 529
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 213
Configuring ATM and MPLS Services
5-66
117374-C Rev 00
Setting the SSCOP Maximum STAT PDU Value
The SSCOP maximum STAT PDU value sets the maximum number of list
elements allowed in a STAT PDU.
The sending device uses this value for segmentation purposes. When the number
of list elements exceeds this value, the STAT message segments. As a general rule,
the default value, 67, causes the STAT PDU to fill six ATM cells using
AAL 5. You can set this value to any odd integer from 3 to 119.
Using the BCC
To change the maximum number of list elements allowed in a STAT PDU,
navigate to the SSCOP prompt (for example,
box; atm/11/1; signaling/11/1;
sscop/11/1
) and enter:
stat-pdu-elements-maximum
<integer>
integer
is the maximum number of elements (any odd number from 3 to 119)
allowed in a STAT PDU.
For example, the following command changes the maximum number of STAT
PDU elements to 81:
sscop/11/1#
stat-pdu-elements-maximum 81
sscop/11/1#
6. Click on
Done
. You return to the Select Connection Type
window.
7. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
(continued)
You do this System responds
Zobrazit stránku 213
1 2 ... 209 210 211 212 213 214 215 216 217 218 219 ... 528 529

Komentáře k této Příručce

Žádné komentáře