Customizing PVC Service Records and PVCs
117374-C Rev 00
6-19
Setting the Receive SDU Size
Bay Networks suggests that you accept the default value of 4608 bytes for the
maximum AAL CPCS SDU size that the PVC supports in the receive direction.
Most packet sizes fall well within this limit. However, you can set the receive
SDU size to any value from 1 to 65,535 bytes.
Using the BCC
To change the receive SDU size for the PVC, navigate to the PVC prompt (for
example,
box; atm/11/1; pvc-service/boston; pvc/11/1/0/32
) and enter:
rx-sdu-maximum
<integer>
integer
is the maximum SDU size that you want the PVC to receive.
For example, the following command changes the maximum receive SDU size to
65,535 bytes:
pvc/11/1/0/32# rx-sdu-maximum 65535
pvc/11/1/0/32#
Using Site Manager
To change the maximum receive SDU size for a PVC, complete the following
tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
ATM
. The Edit ATM Connector window opens.
3. Click on
Service Attributes
. The ATM Service Records List window
opens.
4. Click on the PVC service record that you
want to modify
5. Click on
PVC
. The ATM Virtual Channel Link window
opens.
6. Click on the PVC that you want to modify.
(continued)