Monitoring ATM Using the BCC show Command
117374-C Rev 00
B-15
show dsx3 history
The
show dsx3 history
command displays line, Pbit, Cbit, and Plcp statistics for the
DSX3 circuits in the configuration over specific intervals.
The output includes the following information:
Slot/<Module>/Conn The slot, module, and connector number of the DSX3 circuit.
Circuit Name of the circuit associated with this line.
Sec into Interval The number of seconds into the current interval.
# of Intervals The number of complete intervals.
Line Coding The line coding on this circuit. The line coding options are:
•B3ZS
• HDB3
Line Type Status The line status of the interface. The possible status values are:
•
NoAlarm
- no alarm present
•
RRAI
- receiving yellow remote alarm indication
•
TRAI -
transmitting yellow remote alarm indication
•
RAIS
- receiving Alarm Indications Signal (AIS) failure state
•
TA I S
- transmitting AIS failure state
•
LOF
- receiving Loss of Frame (LOF) failure state
•
LOS
- receiving Loss of Signal (LOS) failure state
•
Loopback
- looping the received signal
•
TestCode
- receiving a test pattern
•
LowSignal
- low signal