Customizing Signaling
117374-C Rev 00
5-61
Modifying SAAL Timers
You can change the default values for SSCOP/SAAL timers. For each timer,
Table 5-4
provides the BCC name, Site Manager name, default value, range, and
description.
Note:
Bay Networks recommends that you leave these timers set to their
default values unless instructed to change them by Bay Networks Customer
Service or your switch provider.
Table 5-4. SSCOP/SAAL Timer Descriptions
BCC Name
Site
Manager
Name
Default
Value Range Description
poll-timer Poll Timer 7 1 to 120 Specifies the SSCOP poll timer value (in tenths of a
second). This value sets the allowable time between
POLL PDU transmissions.
The poll timer ensures that the receiver continues to
return a solicited status (STAT) PDU to the sender on a
regular basis. The timely receipt of STAT PDUs restarts
the poll timer and allows for more efficient transmission
error recovery.
keep-alive-
timer
Keep Alive
Timer
20 1 to 120 Specifies the SSCOP keep alive timer value (in tenths of
a second). This value sets the allowable time between
POLL PDU transmissions if there are no pending
sequence data (SD) PDUs.
The keep alive timer is generally greater than the poll
timer and greater than the length of one round-trip delay.
(continued)