Configuring ATM and MPLS Services
A-40
117374-C Rev 00
Parameter: Protocol Standard
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: UNI_V30
Options: UNI_V30
|
UNI_V31
Function: Specifies how the interface defines Service Specific Connection Oriented
Protocol (SSCOP) frames. Version 3.0 and Version 3.1 SSCOP frames are
incompatible.
Instructions: You must assign the same protocol standard for both the router interface and the
switch. Accept the default, UNI_V30, if the switch uses UNI Version 3.0 to
define SSCOP frames. Select UNI_V31 if the switch uses UNI Version 3.1 to
define SSCOP frames.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.15
Parameter: Max Number of SVC Applications
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 20
Options: 1 to 32767
Function: Specifies the maximum number of SVC applications allowed for this circuit.
The number of SVC applications corresponds to the number of LAN emulation
or IP (RFC 1577) clients allowed for the circuit.
Instructions: Accept the default, 20, or enter a value from 1 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.6