Site Manager Parameters
117374-C Rev 00
A-29
Parameter: Maximum Data Frame Size
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Service
Attributes > LEC
Default: Unspecified
Options: Unspecified
|
1516
Function: Specifies the maximum data frame size (in octets) that this client uses when it
joins an emulated LAN. Clients that use automatic configuration mode use this
parameter in their LE_CONFIGURE_REQUEST frames. Clients that use
manual configuration mode use this parameter in their LE_JOIN_REQUEST
frames.
Accept the default, Unspecified, if you want the client to obtain the maximum
data frame size when it joins an emulated LAN. Select 1516 if you want to
designate the maximum data frame size that this client can:
• Send on the multicast send VCC.
• Receive on the multicast forward VCC.
• Send and receive on data direct VCCs.
Selecting manual configuration mode automatically sets the maximum data
frame size to 1516.
Instructions: Accept the default, Unspecified, or select 1516.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.5.20.1.1.7