Configuring ATM and MPLS Services
A-64
117374-C Rev 00
Parameter: Poll Timer
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Signaling
AAL (SAAL)
Default: 7
Options: 1 to 120
Function: Specifies the Service Specific Connection Oriented Protocol (SSCOP) poll
timer value (in tenths of a second). This value sets the allowable time between
poll protocol data unit (PDU) transmissions.
The poll timer ensures that the receiver continues to return a solicited status
(STAT) PDU to the sender on a regular basis. The timely receipt of STAT PDUs
restarts the poll timer and allows for more efficient transmission error recovery.
Instructions: Accept the default, 7, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.9
Parameter: Keep Alive Timer
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Signaling
AAL (SAAL)
Default: 20
Options: 1 to 120
Function: Specifies the SSCOP keepalive timer value (in tenths of a second). This value
sets the allowable time between poll PDU transmissions if there are no pending
sequence data (SD) PDUs.
The keepalive timer is generally greater than the poll timer and greater than the
length of one round-trip delay.
Instructions: Accept the default, 20, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.10