BayRS Version 15.5.0.0 Document Change Notice
A-26 314470-15.5 Rev 00
PPP Multilink Multiclass Classes Parameter Description
Use the following guidelines to configure the Multilink Multiclass PPP Classes
parameter. In the path name given, bold text indicates that in Site Manager, you
access the PPP Multiclass Classes window by clicking on the Classes button on
the PPP Interface Lists window.
PPP Line Parameter Description
Use the following guidelines to configure the PPP Line parameter associated with
the RFC 2686, “Multi-Class Extension to Multi-Link PPP” feature for BayRS. In
the path name given, bold text indicates that in Site Manager, you access the PPP
Line Lists window by clicking on the Lines button on the PPP Interface Lists
window. For information on configuring other PPP line parameters, see
Configuring PPP Services.
Parameter: Fragment Size
Path: Protocols > PPP > Interfaces > Classes
Default: 80
Options: A value from 64 up to the maximum transmission unit for the circuit.
Function: Specifies the minimum size of a packet that Multilink will fragment for this
class. This parameter is active only for Multilink Multiclass.
Instructions: Accept the default value or specify the required minimum packet size.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.6.1.3
Parameter: Multilink Multiclass for Dialup
Path: Protocols > PPP > Interfaces > Lines
Default: Disable
Range: Enable
| Disable
Function: Enables or disables Multilink Multiclass (RFC 2686) for this line. This
parameter is active only for Multilink on dial-up connections and applies only to
incoming calls.
Instructions: To activate Multilink Multiclass on this dialup line, set this parameter to Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.1.1.51